MR®222LC is an ECOLINE, visible red (under white light) and bright fluorescent orange (under UV), red ferromagnetic liquid cocentrate designed to be used with water which is used for Magnetic Particle Testing (MPT). MR222LC particles is premixed with water conditioner – including corrosion inhibitor, anti-foam and wetting agent; manufactured for an optimum sensitivity, excellent discontinuity definition, colour with minimal to nil background and magnetic characteristics for wet method visible MPT.
It detects surface and slightly sub surface discontinuities such as cracks, inclusions, seams, tears, laps, flakes and other welding defects.
SKU | Pack Size | Case Size |
---|---|---|
2511-0051 | Bulk 1L | 6 |
Properties | Appearance – red-brown liquid Chemical Composition – mixture of magnetic powder & water conditioner Basis – ferro magnetic powder Colour in visible light – red-brown Colour in UV light – fluorescent orange Odour – Odourless |
Approvals | ASME Code V; Art. 7 DIN ISO 9934 (BS 5044) AMS 3044 ASTM E 709 ASTM E1444/1444M ASME RCC-M |
Particle Size | 3-7 µm * *as determined by industrial typical method for measuring particle size |
SAE Sensitivity | 7 ** **as per indications on Ketos ring as defined in ASTM E1444/1444M |
Sediment | 1.2 – 2.4 ml/100ml (1/2h) *** according to ASME ***with a dilution of 40-80 ml / L (in water) |
Recommended Usage | NDT Method – Magnetic Particle Testing (wet method) Application – unfinished to finished surfaces Usage Temperature – 41°F to 131°F / +5 °C to +52 °C Storage Temperature – 41°F to 113°F / +5 °C to +45 °C |
Reference Test Blocks | Reference test block Type 1 (MTU No.3) Reference test block Type 2 Magnetic Field Indication acc. to ASTM E709 (Pie Guage) Test body according to Prof. Berthold Quantitative Quality Indicators Shims (QQI as per AS5371) Magnetic stripe card Type 2000 ASTM centrifuge tube (for fluorescent) acc. to ASME Code V; Art. 25; SE-709 |
Magnetic particle inspection (MPI) is a non-destructive testing (NDT) method used to detect surface and slightly subsurface cracks in ferromagnetic materials such as iron, steel, and nickel. The process involves magnetizing the part to be inspected and then applying appropriate magnetic particles in the form of a dry powder or suspension to the surface of the part. The magnetic particles are attracted to areas of flux leakage, which are areas where the magnetic field is distorted by the presence of a crack or other defect creating a visible indication that can be used to identify and evaluate the nature and extent of the defect.
The application of the magnetic powder creates a visible indication of the location and shape of the crack or other defect. The powder accumulates at the location of the defect, forming a visible indication or "magnetic particle indication." This indication is then examined by a trained inspector using ultraviolet light or other illumination to identify the precise location, size, and orientation of the defect.
MR® Chemie uses its proprietary encapsulation technology for all the Magnetic Powders manufactured in its range making us one of the most advanced Magnetic Particle manufacturers in the world. Through extensive research and development, we have created a product that stands out from the competition, providing unparalleled sensitivity and performance. The advantages of our technology includes:
Through our advanced encapsulation technology, we are proud to offer the best product, providing unparalleled effectiveness and satisfaction to our customers.
Bulk | Aerosol |
---|---|
![]() |